Splenic switch-off in [15O]H2O-PET myocardial perfusion imaging using parametric blood flow images

Journal of Nuclear Cardiology, ISSN 1532-6551, 1071-3581, Page 101868, 10.1016/j.nuclcard.2024.101868

Contributors

Brorson, Jonas (Corresponding author) [1] [2] Gormsen, Lars Christian 0000-0002-0144-1305 [1] [2] Madsen, Simon [1] [2] Tolbod, Lars Poulsen 0000-0002-8105-7046 [1] [2] Jochumsen, Mads Ryø 0000-0002-7676-2322 [1] [2]

Affiliations

  1. [1] Aarhus University
  2. [NORA names: AU Aarhus University; University; Denmark; Europe, EU; Nordic; OECD];
  3. [2] Aarhus University Hospital
  4. [NORA names: Central Denmark Region; Hospital; Denmark; Europe, EU; Nordic; OECD]

Abstract

BACKGROUND: Evaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [15O]H2O-PET with either summed activity images or calculated parametric splenic blood flow images. METHODS: Cohort 1: 90 clinical patients undergoing [15O]H2O MPI in whom adenosine response was considered clinically adequate were identified to characterize the corresponding splenic switch-off. Spleen stress/rest-ratio (SSR-ratio) was calculated as spleen stress signal intensity/spleen rest signal intensity on both summed activity and parametric blood flow images. Cohort 2: Twenty-five patients with repeat MPI due to suspected insufficient adenosine response were identified to observe if splenic switch-off on the initial MPI could predict the outcome of the repeat MPI. Cohort 3: Fifty-four patients who were considered adenosine responders on MPI and who had a coronary angiogram (CAG) follow-up within 3 months after MPI served as a separate validation group. RESULTS: Splenic switch-off was present in most patients with a clinically sufficient adenosine response (Cohort 1), illustrated by both visual (74.4%-86.7%), semi-quantitative (summed activity images) (85.6%), and quantitative (parametric blood flow images) (92.2%) evaluation, which corresponds to the distribution in patients with sufficient adenosine response and follow-up CAG (Cohort 3). In patients suspected of insufficient adenosine response on the initial MPI (Cohort 2), the repeat MPI only yielded different myocardial blood flow (MBF) results if the initial SSR-ratio was >0.90 on splenic parametric blood flow images. CONCLUSION: quantitative splenic switch-off assessment on parametric blood flow images was superior to the semi-quantitative splenic switch-off approach. Patients with a suspected insufficient initial adenosine response and SSR-ratio >0.90 can benefit from a repeat MPI. Thus, the integration of quantitative splenic switch-off using parametric blood flow images in the evaluation of adenosine response may support future clinical decision-making.

Keywords

O-PET, active imaging, activity, adenosine, adenosine response, adenosine stress, angiogram, approach, assessment, blood flow, blood flow imaging, clinic, clinic patients, clinical decision-making, cohort, cohort 1, coronary angiogram, decision-making, distribution, evaluation, flow, flow imaging, follow-up, follow-up coronary angiogram, group, images, integration, intensity, months, myocardial blood flow, myocardial perfusion imaging, myocardial perfusion imaging studies, outcomes, patients, patients suspected, perfusion imaging, quantitative approach, radiotracer signal, respondents, response, semi-quantitatively, signal, signal intensity, spleen, splenic switch-off, stress, stress/rest ratio, study, switch-off, validation group, validity, vasodilation

Funders

  • Novo Nordisk Foundation

Data Provider: Digital Science