Augmented virtual impedance-based fault ride through of islanded microgrids under harmonic and unbalanced conditions

International Journal of Electrical Power & Energy Systems, ISSN 0142-0615, 1879-3517, Volume 157, Page 109845, 10.1016/j.ijepes.2024.109845

Contributors

Arani, Zahra Dehghani 0000-0003-0522-9771 [1] Taher, Seyed Abbas 0000-0002-3998-5332 (Corresponding author) [1] Guerrero, Josep M 0000-0001-5236-4592 [2]

Affiliations

  1. [1] University of Kashan
  2. [NORA names: Iran; Asia, Middle East];
  3. [2] Aalborg University
  4. [NORA names: AAU Aalborg University; University; Denmark; Europe, EU; Nordic; OECD]

Abstract

Reducing the control effort and limiting the output current of grid-forming inverters with the ability of voltage distortion prevenience in islanded microgrids under harmonic and asymmetrical fault conditions are the main objectives of this paper, which have not been investigated so far. In the proposed fault ride through (FRT) approach for inverter-based distributed generation (DG) resource, the current limiting strategy (CLS) only decreases the fundamental component of the reference value of inverter current to a value less than the threshold limit. In other words, harmonic components of the reference value of the inverter current remain unchanged in the proposed CLS to prevent DG’s output voltage distortion. Moreover, an adaptive reference voltage modification scheme is designed based on the virtual impedance concept and by using the reference current reduction coefficient obtained from the proposed CLS. This scheme avoids the voltage controller saturation as well as eliminates the need to use the anti-windup technique for the proportional-resonant (PR) controller. The output impedance-based stability analysis is also performed based on the closed-loop dynamics of the proposed FRT approach to present a basis for the selection of the key parameter. Comparative studies performed by MATLAB/SIMULINK software approve the superior performance of the proposed method under severe asymmetrical faults and different nonlinear loads than an existing peak detection (PD)-based CLS. Furthermore, state space analysis indicates the stability of the proposed control structure with different values for the reference current reduction coefficient specifying the fault depth indirectly.

Keywords

CLS, DG, FRT, FRT approach, MATLAB/Simulink, Matlab/Simulink software, analysis, anti-windup technique, approach, asymmetrical fault conditions, asymmetrical faults, closed-loop dynamics, coefficient, comparative study, components, concept, conditions, control, control efforts, control saturation, control structure, current, depth, distortion, dynamics, efforts, fault, fault conditions, fault depth, fault ride, generation, grid-forming inverters, harmonic components, impedance concept, impedance-based stability analysis, inverter, inverter current, inverter-based distributed generators, islanded microgrid, limitations, load, method, microgrid, modification scheme, nonlinear loads, output, output current, output voltage distortion, parameters, peak, performance, prevenient, proportional-resonant, reduction coefficient, reference, reference values, resources, ride, saturation, scheme, selection, software, space analysis, stability, stability analysis, state, state space analysis, structure, study, superior performance, technique, threshold, threshold limit, values, virtual impedance concept, voltage, voltage distortion, words

Funders

  • The Velux Foundations

Data Provider: Digital Science